NEC 1080Xd Server User Manual


 
Service Processor 3-17
CM (Change Command Mode)
Execution:
This command can be executed in the AC POWER ON state or DC POWER ON state.
Entering Maintenance mode requires the entry of a password.
Function:
Changes from Normal mode to Maintenance mode. When the system is in Maintenance
mode, the Status LED on the front of the server is amber.
Note: The CM command can be executed in Normal mode or
Maintenance mode.
Table 3-19. CM Command Screen
Screen Image Reference
iSPyz:---> cm<ENTER>
Password is needed to enter maintenance mode.
maintenance password : xxxxxxxx <ENTER>
incorrect.
maintenance password : xxxxxxxx <ENTER>
A
Command Mode was changed to maintenance mode. B
Table 3-20. CM Screen References
Reference Description
A To switch from Normal mode to Maintenance mode, a password is required.
If you enter a
wrong password, a message is displayed and the system waits for
another password entry. If you enter an incorrect password three times in a row, the
command terminates.
Passwords are case sensitive.
B After the mode change to Maintenance mode is displayed, the command terminates.