NEC 1080Xd Server User Manual


 
Service Processor 3-45
Table 3-35. HC Subcommands (cont’d)
cmd arg1 arg2 arg3 arg4 Description
pbayxy d h
- Specifies the location and height of the Power
Bay Unit in the cabinet.
x” is the unit ID number.
1: Power Bay Unit
0: Not allowed
y” is the ID number. (0) must be specified.
d” is the position of the lower edge of the unit in
decimal (0-63) by using the EIA unit.
(1 EIA unit = 44.45mm)
h” is the height of the unit (3).
loc
(cont’d)
pcixx c d
Specifies the location and height of the PCIX
Unit in the cabinet.
x” is the PCIX Unit number (1-3).
c” must be (1).
d” is the position of the lower edge of the unit in
decimal (0-63) by using the EIA unit.
(1 EIA unit = 44.45mm).
check - - - - Checks the current configuration information
from the following points:
Presence of units whose location information
is not entered
Presence of “DISABLE” components
Presence of “INVISIBLE” units
Configuration violating the installation
restrictions
Configuration with penalty in
performance/RAS.
This subcommand can be executed in the AC
POWER ON state or DC POWER ON state.