NEC 1080Xd Server User Manual


 
Service Processor 3-29
Table 3-30. EN Screen (cont’d)
Screen Image Reference
---- Temperature (Celsius) [4/4] --------------------------------------- 19:20:57,01/31/2002 ----
current threshold comment
FAN IPMI ACPI
PCIX0(V) 45 - 60/ 62 65
DBP 52 - 60/ 62 65
PCIX1(F) - - - -
IORB - - - -
DBP - - - -
PCIX2(F) 45 - 60/ 62 65
IORB 63 - 60/ 62 65 reported to the software
DBP - - - -
PCIX3(F) 45 - 60/ 62 65
IORB 52 - 60/ 62 65
DBP - - - -
----------------------------------------------------------------------------------------------------------------------
Previous page? (p[revious]/e[xit]/CR=exit) : <ENTER>
Table 3-31. EN Screen References
Reference Description
A Displays the state of the Power Bay/Power Bay Unit in the chassis/cabinet.
If an alarm occurs, an asterisk (*) mark appears at the beginning of the line.
State
ON : Indicates that DC (48V) is supplied to the devices in the cabinet.
OFF: Indicates that DC (48V) is not supplied to the devices in the cabinet.
---: Indicates that no Power Bay Unit exists (not detected by the iSP).
DPSx
(blank): Indicates the normal state.
ALARM : Indicates an alarm state.
---: Indicates that no Distributed Power Supply Module exists
(not detected by the iSP).
((blank): Displays no indication on normal state.)
B Displays the state of the Fan Units located in the Main Chassis and Expansion
Chassis.
If an alarm occurs, an asterisk (*) mark appears at the beginning of the line.
The Fan Units for the CELLV Board have high rotation speed and low rotation speed.
-- : Indicates that it does not exist.
(blank): In the case of XIC Board/XBR Board/PCIV Mother Board, indicates a
normal state.
ALARM: Indicates an alarm state.
low: Indicates low-speed operation state.
HIGH: Indicates high-speed operation state.