NEC 5800/320Lc-R Server User Manual


 
Troubleshooting 7-35
“Source: iANSMiniport
Event ID: 11
Description: Adapter link down: Stratus emb-82544GC Copper Gigabit Adapter
#2.”
“Source: iANSMiniport
Event ID: 13
Description: Secondary Adapter is deactivated from the Team: Stratus
emb-82544GC Copper Gigabit Adapter #2.”
“Source: iANSMiniport
Event ID: 16
Description: Team #X: The last adapter has lost link. Network connection has
been lost.”
“Source: iANSMiniport
Event ID: 35
Description: Initializing Team #X missing adapters. Check the configuration to
verify that all the adapters are present and functioning.”
If the following logs are recorded after the above logs are recorded, there is no real
problem on operation by the above errors or warnings. When the following logs are
not recorded, if the log of the source “sragbe” is not recorded, there is no real problem
on operation by the above errors or warnings.
“Source: iANSMiniport
Event ID: 14
Description: Secondary Adapter has rejoined the Team: Stratus emb-82544GC
Copper Gigabit Adapter.”
“Source: iANSMiniport
Event ID: 15
Description: Adapter link up: Stratus emb-82544GC Copper Gigabit Adapter.”
“Source: iANSMiniport
Event ID: 17
Description: Team #X: An adapter has re-established link. Network connection
has been restored.”
ESMCpuPerf-related logs are recorded in the system event log:
If NEC ESMPRO Agent cannot get performance information from the OS due to a
temporary resource shortage or high load ratio on the system, it will record the
following event log. However, there is no real problem on operation (In the
description, Y and Xrepresent alphanumeric characters).
Source: ESMCpuPerf
Event ID: 9005
Description: Cannot get system performance information now (YYYY
Code=xxxx).
If NEC ESMPRO Agent cannot get information, it will treat the load ratio as 0%.
So, if NEC ESMPRO Agent cannot get information continuously, the CPU load
ratio may appear lower than the actual value.