NEC N8100-1061F Server User Manual


 
4-20 Configuring Your Server
Running the Utility
To run the utility, perform the following procedures:
1. Power on the server.
The following message appears while POST is in progress.
IMPORTANT: The message appears for each additional SCSI
controller.
Adaptec SCSI BIOS Vxxx xxxxx
(c) 2000 Adaptec, Inc. All Rights Reserved
Press <Ctrl> <A> for SCSISelect(TM) Utility! 
2. Press and hold Ctrl and A.
The SCSISelect utility starts and its Main menu appears.
3. Select the channel and press Enter.
AIC-7902 A at Slot 23 02:03:00
AIC-7902 B at Slot 23 02:03:01
NOTE: "AIC-7902A" is for backup file devices. "AIC-7902B" is for
internal SCSI hard disk drives.
The Options menu appears.
4. Select option in the Options box and press Enter.
AIC-7902 at slot 23, 03:03:00
Would you like to configure the SCSI controller, or run the
SCSI Disk Utilities? Select the option and press <Enter>.
Options
SCSI Disk Utilities
Enable HostRAID Support
Configure/View SCSI Controller Settings
If you wish to configure the adapter or a device, select "Configure/View SCSI Controller
Settings".
If you wish to format a disk, verify disk media, or display a list of devices and their SCSI
IDs, select "SCSI Disk Utilities".