8-6 Troubleshooting
Error
code
Error message Recommended Action
02D1 System Memory exceeds the CPU's caching
limit.
02F4 EISA CMOS not write able.
02F5 DMA Test Failed.
02F6 Software NMI Failed.
02F7 Fail-safe Timer NMI Failed.
Contact your service representative.
0B22 Processors are installed out of order. Request the maintenance to replace the CPU.
0B28 Unsupported Processor detected on
Processor 1.
0B29 Unsupported Processor detected on
Processor 2.
Make sure that the server supports the CPU.
If you are not sure, contact your service
representative to request the maintenance.
0B30 FAN1 Alarm occurred.
0B31 FAN2 Alarm occurred.
0B32 FAN3 Alarm occurred.
0B33 FAN4 Alarm occurred.
0B34 FAN5 Alarm occurred.
0B35 FAN6 Alarm occurred.
0B36 FAN7 Alarm occurred.
0B37 FAN8 Alarm occurred.
Contact your service representative to replace
the fan.
0B5F Forced to use Processor with error Because an error is detected in every CPU,
the system is forcibly started. Contact your
service representative.
0B60 DIMM group #1 has been disabled
0B61 DIMM group #2 has been disabled
0B62 DIMM group #3 has been disabled
Contact your service representative.
0B70 The error occurred during temperature
sensor reading.
Contact your service representative.
0B71 System Temperature out of the range. Contact your service representative to replace
the fan.
0B74 The error occurred during voltage sensor
reading.
0B75 System voltage out of the range.
Contact your service representative.
0B80 BMC Memory Test Failed.
0B81 BMC Firmware Code Area CRC check failed.
0B82 BMC core Hardware failure.
0B83 BMC 1BF or 0BF check failed.
Turn off the power once and then on again to
start the server. If the error cannot be
corrected, contact your service representative.
0B8B BMC progress check timeout.
0B8C BMC command access failed.
0B8D Could not redirect the console - BMC Busy -
0B8E Could not redirect the console - BMC Error -
Turn off the power once and then on again to
start the server. If the error cannot be
corrected, contact your service representative.