NEC N8406-019 Switch User Manual


 
- 103 -
Appendix: Connecting Serial Port
The FC Switch Module includes the feature of logging in to the console of the FC Switch Module via a
serial port to provide setting for the FC Switch Module.
To use a serial console, the following jobs are previously required.
Connecting Serial Console
You should login to the serial console of the FC Switch Module from the console of the Enclosure
Manager (EM) card in the Blade Enclosure (SIGMABLADE). For the login from the console of the
EM card in the Blade Enclosure (SIGMABLADE), refer to the User’s Guides of the Blade Enclosure
(SIGMABLADE) and EM card.
The parameters required to connect to the serial port installed on the FC Switch Module should be
set as shown in the table below:
Transmission speed 9600 bps
Data length 8 bits
Parity None
Stop bit 1 bit
Flow control None
The user name and password for the initial login to the console on the FC Switch Module are as
follows:
Administrator authority: Display of FC Switch Module setting information and setting change
User name for FC Switch Module login:admin
Password for FC Switch Module login: password
User authority: Display of FC Switch Module setting information
User name for FC Switch Module login:user
Password for FC Switch Module login: password
Type the user names and passwords for FC Switch Module login with
lowercase letters.
For the serial login to the FC Switch Module from the EM card in a Blade
Enclosure (SIGMABLADE) through Ethernet, refer to the User's Guides of
the Blade Enclosure (SIGMABLADE) and EM card.