NEC N8406-019 Switch User Manual


 
- 55 -
4-5. Checking Connections of Peripherals
Confirm that the FC Switch Module normally recognizes fibre channel devices according to the
following procedure:
1. Type "switchshow" on the console.
Confirm that the fibre channel devices are normally linked up.
If a fibre channel device already connected to the FC Switch Module does
not appear in the result of the "switchshow" command, check the following:
Whether the connected fibre channel device operates normally, and
Whether the FC cable is connected securely.
2. Type "nsshow" on the console.
Confirm that the information on the fibre channel devices is normally registered to the
relevant name server.
Check the following if the information on a fibre channel device already
connected does not appear in the result of the "nsshow" commend:
Whether the connected fibre channel device operates normally and
Whether the FC cable is connected securely.
A fibre channel device is registered for a port as a result of "switchshow" but
the information on the fibre channel device may not appear as a result of the
information on the same port by "nsshow". If so, some device connection
error may occur. Take proper action according to the User’s Guide of the
fibre channel device you use.
See "Appendix Checking Connections of Peripherals" for how to check the
connection of each peripheral.