NEC NDA-24233 Network Card User Manual


 
Page 3-36 NDA-24233 Issue 2
Console Command List VisuaLink 128/384 Engineering Guide
3.8 Alarm Related Command
CALM Read Alarm Status (1 of 2) 8-1
Description: Acquires alarm status. This is used to check the information of a generated
alarm and the loopback status.
Command Format: CALM
Response: Normal Response: p1 p2 p3 p4 p5 p6 OK
p1: 00-FF : CPU/ VIDEO alarm
p2: 00-FF : LINE alarm
p3: 00-FF : H221 alarm
p4: 00-FF : Bonding alarm
p5: 00-FF : TEST status
p6: 00-FF : TEST status 2
p1: CPU/VIDEO alarm
D0: CPU alarm 0: normal 1: abnormal
D1: FAN alarm 0: normal 1: abnormal
D2-3: Unused 0: fixed
D4: VIDEO alarm 0: normal 1: input cut
D5-7: Unused 0: fixed
p2: LINE alarm
D0-3: Unused 0: fixed
D4: Line 1 SYNC alarm 0: normal 1: abnormal
D5: Line 2 SYNC alarm0: normal 1: abnormal
D6: Line 3 SYNC alarm0: normal 1: abnormal
D7: Unused 0: fixed
p3: H221 alarm
D0: REC alarm 0: normal 1: abnormal
D1: CRC alarm 0: normal 1: abnormal
D2-7: Unused 0: fixed
D7 D6
D5
D4
D3
D2
D1
D0
D7 D6
D5
D4
D3
D2
D1
D0
D7 D6
D5
D4
D3
D2
D1
D0