NEC NDA-24233 Network Card User Manual


 
NDA-24233 Issue 2 Page 3-73
VisuaLink 128/384 Engineering Guide Console Command List
3.31 Other Report Command
CGSI Automatic Activation File Starting Report 31-1
CGEI Automatic Activating File Ending Report 31-2
Description: This is a report to show the start of auto executed file.
Command Format: CGSI p1
p1: 0-7 : number of file for auto executed file
Description: This is a report to show the completion of auto executed file.
Command Format: CGEI p1 p2
p1: 0-7 : number of file for auto executed file
p2: xxxxx : ending result
xxxx : OK : normal ending
EMPTY : no data
EX ERR : access error
CMD ERR : command execution error