Nokia WAP and SMS gateway Network Card User Manual


 
Chapter 5. Setting up a SMS Gateway
Variable Value Description
interface-version number
Change the "interface version"
parameter sent from Kannel to a
value other then 0x34 (for SMPP
v3.4). the value entered here
should be the hexadecimal
representation of the interface
version parameter. for example,
the default (if not set) is "34"
which stands for 0x34. for SMPP
v3.3 set to "33".
address-range (m) string
According to the SMPP 3.4 spec
this is supposed to affect which
MS’s can send messages to this
account. Doesn’t seem to work,
though.
our-host string
Specicy the outgoing IP address
for connections from a
multi-homed machine. If this is
not defined the default device of
the machine will be used.
my-number number
Optional smsc short number.
Should be set if smsc sends a
different one.
enquire-link-interval number
Optional the time lapse allowed
between operations after which
an SMPP entity should
interrogate whether it’s peer still
has an active session. The default
is 30 seconds.
max-pending-submits number
Optional the maximum number
of outstanding (i.e.
acknowledged) SMPP operations
between an ESME and SMSC.
This number is not specified
explicity in the SMPP Protocol
Specification and will be
goverened by the SMPP
implementation on the SMSC.
As a guideline it is recommended
that no more than 10 (default)
SMPP messages are outstanding
at any time.