161
CrossFire 8600/8605 Token-Ring Switches v. 1.2, P/N: 710001641 Monitoring the Network with the Console
Station-CPort Information...
Displays the
Station-CPort Information
screen.
TXI Information Screen
The
TXI Information
screen provides information about IEEE 802.5 DTR MAC
TXI.
Authorized Function Classes
Functional classes that a node is enabled to transmit. This field displays the value
set by the Authorized Function Classes subvector X'06' of the Change Parameters
MAC frame. Valid range is from
0x0000
to
0xFFFF
. Each bit that is enabled('1')
corresponds to a function class that is enabled.
Error Report Timer
Timeout value of the ring station’s soft error report timer. This field displays the
value of the timer TSER as set by the Error Timer Value subvector X'05' from the
Change Parameters or the Initialize Station MAC frame. This object indicates the
value in .01 second increments.
Physical Drop Number
Physical location of the sending ring station. This field displays the value set by the
Assign Physical Drop Number subvector X'04' of the Change Parameters or the
Initialize Station MAC frame. Valid range is from
0x00000000
to
0xFFFFFFFF
.