Olicom 8605 Switch User Manual


 
217
CrossFire 8600/8605 Token-Ring Switches v. 1.2, P/N: 710001641 Cable and Pin Information
Cable Length and Lobe Wiring Rules for Dedicated-Media
LAN Segments
The Olicom Token-Ring network dedicated-media (full-duplex) connections
support only one attached entity (workstation or switch) per connection.
In a Token-Ring network, the section of cable that attaches a device to an access
unit is called a lobe.
CrossFire 8600 Token-Ring Switch
The tables in this section specify the maximum supported lobe lengths for the types
of cables listed below. An additional 10 m (33 ft) per lobe length is allowed to
accommodate patch cables, unless otherwise specified.
Ring
Speed
Types
1 and 1A
Types
2 and 2A
Type 8 Type 9
4 Mbps 750 m (2,460 ft) 750 m (2,460 ft) 376 m (1,234 ft) 500 m (1,640 ft)
16 Mbps 430 m (1,410 ft) 430 m (1,410 ft) 215 m (705 ft) 295 m (968 ft)
100 Mbps 90 m (295 ft)
See the
Note
below!
Not Supported Not Supported Not Supported
Note
: An additional 10 m (33 ft) UTP 100 Ohm CAT.5 lobe length and a
maximum of two UTP/STP converters without impedance transformation
is allowed to accommodate connection to the STP cabling. The UTP/STP
converter must be specified for 100 MHz operation.
Table 28. Lobe Length for 150 Ohm Shielded Media
Ring Speed 100 Ohm Type 3 100 Ohm Category 3
4 Mbps 100 m (328 ft) 250 m (820 ft)
16 Mbps Not Supported 100 m (328 ft)
100 Mbps Not supported Not Supported
Table 29. Lobe Lengths for 100 Ohm Shielded or Unshielded Cable