Omega Speaker Systems LCIC-WIM-BEN Network Card User Manual


 
70
E.4 Filling Parameters
Notes
1. There is a set of
three
setpoints. Once they are specified (using the Settings
utility), the user may switch to another setpoint
without needing a PC
. This gives
more flexibility when several setpoints are needed. For details about the switching
procedure refer to section E.2.
2. These setpoints are
absolutely different
from the four
general
setpoints (section
3.3.1.3). The general setpoints are inactive in the Fill mode.
Filling By
Weight
Means that Setpoint is defined in weighing units.
Time
Means that Setpoint is defined in time units.
E.4.1 Filling By = Weight
E.4.1.1 Filling by Weight Parameters
Setpoint #x
The required
total
filling weight when the user selects
setpoint #x (x = 1, 2 or 3).
Slow Amount
The required slow filling weight, in % of the current Setpoint
(a tip shows the value of Slow Amount in weight units).
Specify ‘0’ when only one speed is required.
Filling Timeout
Time limitation for the filling process (in ms).
Note: The ‘Filling Timeout’ parameter is
common
for all the three
setpoints. Therefore, specify a ‘Filling Timeout’ value large enough
to cover all the setpoints used.