72
E.4.1.3 Valid Results Limits
The resulting filling weight should normally be inside a user
pre-defined ‘valid range’. In case the weight exceeds that range,
an error situation will occur. Specify ‘Valid Limits (±)’= 0 if you don’t
need this check.
Start from filling # …
Specifies the first filling to be checked, letting you disregard some
filling until the board learns the system thus gives good results. For
example, if 7 is specified, then no error situation will occur upon the first
6 fillings, whatever the results will be.
Valid Limits (±) … %
Specifies the acceptable deviation for a valid result, as a percent of the
current setpoint (a tip shows the value of that acceptable deviation in
weight units).
For example, if the current setpoint = 100 kg and ‘Valid Limits (±)’ =
1%, then the result will be considered as ‘valid’ when it is in the range
[99,101] kg. Otherwise, error #101 or #102 will occur. Specify ‘Valid
Limits (±)’= 0 if you don’t need the ‘Valid Results Limits’ check.