71
Auto Correction &
Averaging x last fillings
When ‘Auto Correction’ is checked, the board tries to correct the
filling amount, based on the results of the last x fillings.
E.4.1.2 Auto Tare
Activate
• When not checked, the Setpoint defines the requested final
gross weight.
That is, if the setpoint is 100 kg and the starting gross weight
is 90 kg, the filling amount will be 10 kg.
The next two parameters (Hi/Lo Limits) are irrelevant.
• When checked, the Setpoint defines the requested filling
amount.
That is, if the setpoint is 100 kg, the filling amount will also
be 100 kg, regardless of the starting gross weight.
However, the filling operation will take place only if the
starting gross weight, as found in accordance with the
Stabilization Criterion (section E.4.1.4), is within the range
defined by the following two parameters (Hi/Lo Limits).
Otherwise, the filling operation will be rejected and an error
will be reported.
Hi Limit
When ‘Auto Tare’ is activated, specifies the high allowed tare limit.
Lo Limit
When ‘Auto Tare’ is activated, specifies the low allowed tare limit.