Omron BU3002SW Power Supply User Manual


 
[Explanation of software functions]
1 Auto shutdown The computer can be shut down automatically when a problem occurs with the power supply.
2 UPS monitoring (operating status) The operating status of the UPS can be monitored (in Commercial Power Mode/Battery Mode).
3 UPS monitoring (data) Monitoring can be performed for input voltage value, connection capacity, battery capacity, etc.
4 Pop-up notification When a problem such as a power failure occurs, a pop-up window that shows the details of the problem can be displayed.
5 Shutdown when OS is inactive Shutdown can be performed when the computer is in an inactive state.
The operating status is retained at shutdown in inactive state, so operation details are not lost.
6 Auto file save Files such as open Word and Excel documents are automatically saved at shutdown.
7 Schedule operation Schedule settings can be made for UPS stop/start.
8 UPS setting change UPS settings (beep ON/OFF, etc.) can be changed. (Items that can be set vary according to the UPS.)
9 External command execution By executing commands at shutdown, items such as application programs can be launched.
10 Event log save Information of events that occur on the UPS (power supply problems, setting changes, occurrences of failure, etc.) are saved as a log.
11 Data log save Data of input/output voltage value, connection capacity, etc. is periodically saved as a log (the save frequency can be set).
12
Coordinated shutdown When a problem occurs with the power supply, multiple computers connected to the UPS can coordinate to perform auto shutdown.
13 Output receptacle control The UPS output receptacles can be individually set to ON/OFF.
14 Redundant power supply support Two or more UPS can be connected to computers equipped with redundant power supply.
Shutdown is not performed when a power supply proble affects only one of the units.
Shutdown is performed only when a power supply problem occurs with both UPS, so the system's operating rate is improved.
15 Remote UPS management The UPS can be managed remotely from a computer on the network.
16 Mail send When a problem such as a power failure occurs, a notification email describing the problem can be sent to the system administrator.
17 SNMP management UPS management information can be sent to the SNMP manager.
18 Telnet connection Settings such as shutdown parameters can be made via the Telnet connection.
19 SYSLOG support UPS management information can be recorded in SYSLOG.
Windows Server 2003 x64 Edition
Windows XP x64 Edition
Windows Server 2003
Windows XP/2000
Windows NT4.0
Windows Me/98
Linux (Note 4)
Mac OS X v10.4/Server v10.4
Mac OS X v10.3/Server v10.3 (Note 5)
Auto shutdown
UPS monitoring (operating status)
UPS monitoring (data)
Pop-up notification
End when OS is inactive (Note 3)
Auto file save (Note 3)
Schedule operation
UPS setting change
External command execution
Event log save
Data log save
Coordinated shutdown
(shutdown of multiple units)
Output receptacle control
Redundant power supply support
Remote UPS management
Mail send
SNMP management
Telnet connection
SYSLOG support
Required options
Connection cable
BUC26
SNMP/Web
card SC20G
Function
Software title
General applications
(Simple functions, standalone)
UPS service
driver
OS standard
UPS service
PowerAct Pro
SNMP/Web
card
UPS Power
Manager (Mac)
Network management
applications
(Advanced functions,
network support)
SNMP management
applications
(Advanced functions,
network support)
Compatible OS
Software function
Standard Option Limited
Note 1: The UPS stops automatically only when the battery is depleted. (Battery Mode continues until the battery is depleted.)
Note 2: Only the battery capacity can be monitored.
Note 3: This function can be used with Windows only. It cannot be used with Linux.
Note 4: For the latest information, check our website at: http://www.omron.co.jp/ped-j/product/soft/index.htm
Note 5: Compatible only with Macintosh computers equipped with PowerPC CPU.
(Note 2)
(Note 1)
• UPS monitoring software function list