65
V400-H111/211
User’s Manual
Section 4 Creating Setting Files Using the 2DCR Configear
Section 4
System Settings
Function Settings
Make the following settings in the [Function Settings] tab of the Create Setting Data
Window.
The default settings are indicated with an asterisk.
■ Data Accumulation
Set whether to collect data.
The Memory Card must be inserted in the Handheld 2D Code Reader to use this
function.
When this function is ON, read data will be saved in a file with the following name in the
Memory Card’s READDATA folder. The READDATA folder will be automatically
generated if it does not already exist.
READ****.csv
Note: The digits indicated by **** start at 0000 and increment by 1 for approximately
each 40 kilobytes.
After reading is completed, the data is written to the Memory Card, which will take
several seconds.
Setting item Settings
Trigger Mode Level Trigger
*
or Alternate
Buzzer ON
*
or OFF
Sleep Shift Time Between 30 sec
*
and 120 sec
NG output (N
)ON or OFF
*
Data Accumulation OFF
*
or ON
Display(Y
) Normal*/Mode A/Mode B/Mode C
Lighting (H
) V400-H111 Auto*/Oblique/R-coax/G-coax/B-coax
V400-H211 Auto*/Oblique/Coaxial