76
Option settings
MEASURE MODE
MEASURED DATA
TARGET DATA
AUTO TESTPATTERN ON
:MENU SELECT
ENTER:SUB MENU
MEASURE MODE
MEASURED DATA
TARGET DATA
AUTO TESTPATTERN ON
MEASURE MODE
MEASURED DATA
TARGET DATA
AUTO TESTPATTERN ON
TARGET DATA
R, G, B
Cy, Mg, Ye, Wh
TARGET DATA: R, G ,B
R x 0.630
y 0.340
G x 0.310
y 0.595
B x 0.155
y 0.070
:MENU SELECT
:ADJUST
MEASURED DATA
Bk Y 5
x 0.313
y 0.329
R Y 2126
x 0.640
y 0.330
G Y 7152
x 0.300
y 0.600
:MENU SELECT
:ADJUST
Adjusting the color matching using a colorimeter
The “R”, “G”, “B”, “Cy”, “Mg”, “Ye” and “Wh” colors can be changed to the desired hues using a colorimeter which is
capable of measuring the chromaticity coordinates and luminance.
<Inputting the current luminance and chromaticity
coordinates>
Press the “MENU” button.
The MAIN MENU screen will be displayed.
Select “OPTION” with the
buttons.
Press the “ENTER” button.
The OPTION screen will be displayed.
Select “COLOR MATCHING” with the
buttons.
Select “MEASURE” with the
buttons.
Press the “ENTER” button.
The MEASURE MODE screen will be displayed.
Use the colorimeter to measure the
luminance (Y) and chromaticity
coordinates (x, y).
Select the colors with the
buttons, and select their values with
the buttons.
After all the data has been input, press
the “MENU” button.
The MEASURE MODE screen will be displayed.
<Inputting the coordinates of a desired color>
Select “TARGET DATA” with the
buttons.
Press the “ENTER” button.
The TARGET DATA screen will be displayed.
Select “R, G, B” or “Cy, Mg, Ye, Wh”
with the buttons.
Press the “ENTER” button.
The TARGET DATA: R, G, B (or “Cy, Mg, Ye, Wh”)
screen will be displayed.
Select the desired colors with the
buttons, and input their coordinates
with the buttons.
After all the data has been input, press
the “MENU” button.
Select “MEASURED DATA” with the
buttons.
Press the “ENTER” button.
The MEASURED DATA screen will be displayed.