47
Others
46
Indicators
There are two indicators on the control panel of the projector which give
information about the operating condition of the projector. These indicators
illuminate or flash to warn you about problems that have occurred inside the
projector, so if you notice that one of the indicators is on, turn off the power
and check the table below for the cause of the problem.
Problem
Indicator
display
Flashing (red)
(Lamp unit on)
The surrounding
temperature or the
temperature inside
the projector has
become unusually
high.
Illuminated (red)
(Lamp unit on)
The temperature
inside the projector
has become
dangerously high, or
the temperature has
suddenly changed.
BThe ventilation holes may be covered.
BThe ambient temperature in the place of use may be too high.
BThe air filter may be blocked.
BUncover the ventilation holes.
BSet up the projector in a place where the temperature is
between 0 °C (32 °F) and 40 °C (104 °F) and the humidity is
between 20% and 80% (with no condensation). [If you set the
FAN CONTROL to “HIGH” (page 41), set up the projector in a
place where the temperature is between 0 °C (32 °F) and 35 °C
(95 °F) and the humidity is between 20% and 80% (with no
condensation).]
BTurn off the MAIN POWER switch by following the procedure
on page 27, and then clean the air filter (refer to page 48).
Possible
cause
Remedy
The surrounding
temperature or the
temperature inside
the projector has
become dangerously
high, causing the
lamp unit to be
automatically shut
off.
Flashing (red)
(Lamp unit off)
TEMP indicator
Remedy
Problem
Indicator
display
Flashing (red)
It is nearly time to
replace the lamp
unit.
Illuminated (red)
An abnormality has been detected in the lamp
circuit.
BDoes “REPLACE
LAMP” appear on
the screen after
the projector is
turned on?
BThis occurs when
the operation time
for the lamp unit is
nearing 1 800
hours. (when
LAMP POWER
has been set to
“HIGH”) Ask your
dealer or an
Authorised
Service Center to
replace the lamp
unit.
Possible
cause
BThe power may
have been turned
on straight away
after it was turned
off.
BWait for a while
until the lamp unit
cools down before
turning the power
back on again.
BThere may be an
abnormality in the
lamp circuit.
BTurn off the MAIN
POWER switch by
following the
procedure given
on page 27, and
then contact an
Authorised
Service Center.
LAMP indicator
NOTE:
BBe sure to turn off the MAIN POWER switch by following the procedure
given in “Turning off the power” on page 27 before carrying out any of the
procedures in the “Remedy” column.
BIf the main power turns off after the TEMP indicator starts flashing, it
means that an abnormality has occurred. Please contact an Authorised
Service Center so that the necessary repairs can be made.