Chapter 4Settings — [3D SETTINGS] menu
94 - ENGLISH
[3D WAVEFORM MONITOR]
[OFF] Hides the 3D waveform monitor.
[ON] Displays the 3D waveform monitor.
Note
f The [CLOCK PHASE] setting is enabled at simultaneous input of RGB1 and RGB2 to adjust the right eye image.
f This is disabled when [3D SYSTEM SETTING] is set to other than [SINGLE].
f This is disabled when [3D TEST PATTERN] is displayed.
f This is disabled when [3D TEST MODE] is set to other than [NORMAL] or [SIDE BY SIDE].
f The 3D waveform monitor is displayed only when the [3D PICTURE BALANCE] screen is displayed.
f The normal waveform monitor cannot be displayed in 3D images.
[DARK TIME SETTING]
Set the black display period to be displayed between the right eye image and the left eye image as necessary for the 3D system used.
1) Press as to select [DARK TIME SETTING].
2) Press qw to switch the item.
f The items will switch each time you press the button.
[0.5 ms]
Set so that the 3D setting is displayed correctly.
[1.0 ms]
[1.5 ms]
[2.0 ms]
[2.5 ms]
[2.7 ms]
Note
f This is disabled when [3D SYSTEM SETTING] is set to other than [SINGLE].
f When the setting does not correspond to the 3D system in use, phenomenon such as increased crosstalk and darkening of displayed
images may occur.
[3D FRAME DELAY]
Adjust the timing of the left-right switch of an image.
1) Press as to select [3D FRAME DELAY].
2) Press qw to switch the item.
[0us] - [25 000 us] Allows you to set in increments of 10 us.
f The adjustment range depends on the input signal.
[3D TEST MODE]
Set the image display system for use with 3D system adjustments.
1) Press as to select [3D TEST MODE].
2) Press qw to switch the item.
[NORMAL] Standard setting.
[SIDE BY SIDE] The left eye image is displayed on the left, next to the right eye image displayed on the right.
[LEFT/LEFT] Both the left eye image and right eye image display the left eye input signal.
[RIGHT/RIGHT] Both the left eye image and right eye image display the right eye input signal.
[LEFT/BLACK]
The left eye input signal is displayed in the left eye image and a completely black image is displayed
in the right eye image.
[BLACK/RIGHT]
A completely black image is displayed in the left eye image and the right input signal is displayed in
the right eye image.
Note
f The [3D TEST MODE] settings return to [NORMAL] when the projector is switched off.
f This is disabled when [3D SYSTEM SETTING] is set to other than [SINGLE].
f This is disabled when [3D TEST PATTERN] is displayed.