Panasonic WJ-NT204 Network Card User Manual


 
144
Default Settings
The default settings in the menus and DIP switch positions are shown below. The settings in the menus will return to the default
values after you implement the initializing operation.
Default Settings in the menus
Menu # & Title Item Initial Value Note
100 CONFIGURATION MODE TRANSMITTER
IP ADDRESS 192.168.0.10
SUBNET MASK 255.255.255.0
DEFAULT GATEWAY 0.0.0.0
DATE/CLOCK 01.01.01 00:00
DAYLIGHT SAVINGS OFF
TRANS. CONTROL ON
210 RECEIVING REGI. READY STATE AUTO
COM.STATE AUTO
RINGER ON
220 CALLING IP ADDRESS CHECK CALLING IP ADDRESS CHECK OFF
REJECT IP/SUBNET MASK
Specify the addresses
ACCEPT IP/SUBNET MASK
Specify the addresses
320 ONE-TOUCH DIAL REGI. From No. 1 to No. 5
No. 1(001), No. 2(002), No. 3(003),
No. 4(004), No. 5(005)
330 SEQ. DIAL START UP SEQ. DIAL 001
COM TIME 20S per site
REPEAT NO
410 RE-CONNECTION RE-CONNECTION ON
421 SERIAL DATA PORT RATE 9600
DATA BIT 8
STOP BIT 1
PARITY NONE
MODE PSD
RS485 UNIT # 002
422 HOST PORT RATE 9600
RS485 UNIT # 001
430 VIDEO SWITCH SETUP VIDEO SWITCH No. 1 thru 8 Point # VIDEO SEQ CAM # PRESET # TRIGGER OUT ALARM
1ON 1 1 1 ON
2ON 2 1 2 ON
3ON 3 1 3 ON
4ON 4 1 4 ON
5 ON AUX NONE 5 ON
6ON 1 2 6 ON
7ON 1 3 7 ON
8ON 1 4 8 ON
440 AUDIO AUDIO SEND G711-mu
451 VIDEO BIT RATE MOTION VIDEO BIT RATE(kbps) 1024
MOTION NORMAL
452 ON SCREEN DISPLAY VIDEO INPUT DISP ON
TITLE DISP ON
CLOCK DISP ON
453 CABLE COMPENSATION CAMERA 1-4 S(Short)
461 ALARM SETUP ALARM TYPE EDGE(CLOSE)
ALARM AUTO DISC ON
ALARM AUTO DISC TIMER 60S
ALARM DIALING TIME TABLE1-3 DAY(MON-SUN), TIME(00:00-00:00)
462 ALARM DIALING TABLE 1 ALARM 1-8 ALARM 1-8: #1-#3 (SELECT)
463 ALARM DIALING TABLE 2 ALARM 1-8 ALARM 1-8: #1-#3 (SELECT)
464 ALARM DIALING TABLE 3 ALARM 1-8 ALARM 1-8: #1-#3 (SELECT)
465 ALARM PORT SETUP PORT 1-8 Enabled
470 SEQ. SCAN SETUP SEQ. SCAN OFF
DWELL TIME 05S
RESTART TIME 060S
481 LOCK MENU LOCK OFF
NUM (Numeric buttons) LOCK OFF
FUNCTION (Function buttons) LOCK OFF
482 MENU ENTER NEW PASSWORD SELECT