Panduit TDP42H Printer User Manual


 
PANDUIT TDP4*HGMTDPH-MAN
Page 6-4
Section 6: Interface Specifications
ELECTRICAL SPECIFICATIONS
Printer Connector AMP 57-40360 (DDK) or equivalent
Cable Connector AMP 57-30360 (DDK) or equivalent
Cable IEEE1284 Parallel, 10 ft. (3 m) or less
Signal Level High = +2.4V to +5.0V
Low = 0V to -0.4V
DATA STREAMS
<ESC>A . . Job#1 . . <ESC>Z<ESC>A . . Job#n . . <ESC>Z
IEEE1284 Parallel Interface Pin Assignments
PIN SIGNAL DIRECTION PIN SIGNAL DIRECTION
1 STROBE To Printer 19
STROBE
Return
Reference
2
DATA 1 To Printer 20
DATA 1 Return
Reference
3
DATA 2 To Printer 21
DATA 2 Return
Reference
4
DATA 3 To Printer 22
DATA 3 Return
Reference
5
DATA 4 To Printer 23
DATA 4 Return
Reference
6
DATA 5 To Printer 24
DATA 5 Return
Reference
7
DATA 6 To Printer 25
DATA 6 Return
Reference
8
DATA 7 To Printer 26
DATA 7 Return
Reference
9
DATA 8 To Printer 27
DATA 8 Return
Reference
10
ACK To Host 28
ACK Return
Reference
11
BUSY To Host 29
BUSY Return
Reference
12
PTR ERROR To Host 30
PE Return
Reference
13
SELECT To Host 31
INIT
From Host
14
AUTOFD
(1)
To Host 32
FAULT
To Host
15
Not used 33
Not Used
16
Logic Gnd 34
Not Used
17
FG Frame Ground 35
Not Used
18
+5V (Z=24K ohm) To Host 36
SELECTIN
(1)
From Host
(1) Signals required for IEEE 1284 mode.