Paradyne 3162 Network Card User Manual


 
SNMP MIB Objects
E-22
3162-A2-GB20-30March 1999
Generic Interface Test Table, Generic Interface MIB
The test table provides access to additional tests (loopbacks and pattern tests)
that are not in the interface group of MIB II.
Generic Interface Test Table – “ifExtnsTestType” Object (ifExtnsTestEntry 4)
This object is a control variable used to start and stop operator-initiated tests on
the interface. It provides the capability to:
H Start/stop the Monitor QRSS test pattern on the network interface.
H Start/stop the Send QRSS/511 test pattern on a synchronous data port.
H Start sending a V.54/FT1 UP/DOWN code to the remote unit for a
synchronous data port.
H Start/stop the Monitor QRSS/511 test pattern on a synchronous data port.
H Start/stop the DCLB/DTLB loopback test on a synchronous data port.
The following object identifiers are used to control the tests on the interface.
H noTest – Stops the test in progress on the interface.
H testFullDuplexLoopBack – Initiates a DCLB on the interface. Only supported
for the data ports.
H testLoopDTLB – Initiates a DTLB on the interface. Only supported for the
data ports.
H testMonQRSS – Initiates a Monitor QRSS test on the interface. Supported for
the data ports and the network interface.
H testMon511 – Initiates a Monitor 511 test on the interface. Only supported for
the data ports.
H testSendQRSS – Initiates a Send QRSS test on the interface. Only supported
for the data ports.
H testSend511 – Initiates a send 511 test on the interface. Only supported for
the data ports.
H testSendV54Up – Sends a V54 up code to the remote unit. Only supported
for the data ports.
H testSendV54Down – Sends a V54 down code to the remote unit. Only
supported for the data ports.
H testSendFT1Up – ends a FT1 up code to the remote unit. Only supported for
the data ports.
H testSendFT1Down – Sends a FT1 down code to the remote unit. Only
supported for the data ports.