Paradyne 3615 Network Card User Manual


 
Operating the DSU
4-213615-A2-GB20-20 December 1996
Front Panel (DCP) Security
NOTE
This page can be removed to
prevent unauthorized persons
from learning about the security
access levels and their
selection.
The Model 3615 diagnostic control panel (DCP) and
Model 3616 shared diagnostic control panel (SDCP) have
two levels of security access, as shown in T
able 4-8.
Table 4-8
Security Access Levels
Security
Access Level
Functions Available
Unlock All
Lock Local branch only:
S Status branch
S Configuration branch:
Display only (no changes)
S Control branch:
Display External Leads only
(no changes)
The DualFlow DSUs are shipped from the factory with
the security level set to
Unlock. When the DCP is locked,
only the Local branch appears on the control DSU and no
settings can be changed or saved.
If the security has not been set on the DCP before, the
following appears:
F1
FP
A
ccess: ? ? ?
Lock Unlock Save
F2
F3
To
select the security level:
. Procedure
1.
Press the
key to ensure that you are at the
top-level menu.
2.
Press the
and
keys simultaneously for
three seconds. The following menu appears:
F1
FP
A
ccess: Unlock
Lock Unlock Save
F2
F3
3. Select the security level:
Lock – T
o restrict access
Unlock – T
o provide full access
Press the appropriate function key (F1 or F2).
4.
Select
Save (F3).