Status Indicators and Control Panel Messages
C-53615-A2-GB20-20 December 1996
Table C-3
(2 of 3)
Device Health and Status Messages
ConditionMessage
Dial Tone:Fail Dial tone test was enabled and test failed.
DDS F:
alarm
Digital facility alarm;
alarm
is one of the following network alarms:
BiplrViol Excessive Bipolar Violations
Fac Alarm Facility Alarm
OutofServc Out-of-Service condition
No Signal No signal has been received
DSU:Device Fail Internal failure in the DSU is detected. (Go to the Test branch for Device Test.)
DSU:Disable DSU transmitter is disabled. (Go to the Control branch to enable the DSU.)
DSUTst:
test
,
init
The DSU is running a test, initiated from
init
.
test
is one of the following tests:
BERT Bit Error Rate Test
BiL Bilateral Loopback
Dev Device Test
DL Digital Loopback
DT Digital Test
DTE DTE Loopback
Lamp Lamp Test
NetL Network Loopback
TM Test Mode
init
is one of the following initiators:
DCP Diagnostic Control Panel
DTE Data T
erminal Equipment
NMS Network Management System
Ntwk Network
Remt Remote DSU
External Alarm A The DSU detects a positive voltage on Pin 23. This alarm condition is defined by the
Ext Leads configuration option.
External Alarm B The DSU detects a positive voltage on Pin 19. This alarm condition is defined by the
Ext Leads configuration option.
Invalid Address A DSU was powered up with an invalid address. Invalid addresses are:
0
This is reserved for the SDU
192
This is reserved for the broadcast address
191
Invalid for a DSU with a DBM because of the reserved 192
broadcast address
255
Invalid for a DSU with a DBM