Paradyne 3830 Network Card User Manual


 
COMSPHERE 3800 Series Modems – Model 3830
4-30 August 1998 3830-A2-GB91-30
S-Register List
S-Registers affect the operating parameters of the Model 3830 modem.
These registers are applicable only when the DTE Dialer Type
configuration option is set for AT. (See &Mn and &Qn commands.)
S-Registers can be displayed and/or modified when the modem is in
Command mode. To display the value of an S-Register, issue the
following command:
TYPE: ATSn?
Where: n is the register number.
PRESS: Enter
To modify the value of an S-Register, issue the following command:
TYPE: AT Sn=r
Where: n is the register number, and r is the new value.
PRESS: Enter
Table 4-3 lists all S-Registers supported by the Model 3830.
Table 4-3
(1 of 20)
Model 3830 S-Registers
S0 Auto-Answer Ring Number
Determines the number of rings the modem will count before
automatically answering a call.
Enter zero (0) if you do not want the modem to automatically answer any
calls. Otherwise, enter a value from 1–255 for the number of rings to
count before answering. Note that if disabled, the modem can only
answer with an ATA command.
Factory setting is 1.