Paradyne 3830 Network Card User Manual


 
COMSPHERE 3800 Series Modems – Model 3830
4-34 August 1998 3830-A2-GB91-30
Table 4-3
(5 of 20)
Model 3830 S-Registers
S35 Auto Redial (Leased Line)
Auto Redial allows repeated automatic dial backup attempts by specifying
the range of Directory Locations that can be tried. A redial attempt is
made in response to a bad phone number, a busy signal, no answer, or
no quiet answer. The modem must be in Originate mode.
On leased lines with dial backup, Auto Redial works in conjunction with
the Bad Lines Auto Originate and Rate Auto Originate options.
Register has the following values:
0 = Use Directory Location 1
1 = Use Directory Locations 1–2
2 = Use Directory Locations 1–3
3 = Use Directory Locations 1–4
S S S
S S S
9 = Use Directory Locations 1–10
NOTE:The modem must be in Originate mode to perform an automatic
dial backup.
S36 Rate Auto Originate
Initiates a dial backup call, using the phone number in directory location
1, when the leased-line rate of the modem falls back to or below a certain
speed.
Register has the following values:
0 = Disable
1 = On fallback to 4,800
2 = On fallback to 7,200
3 = On fallback to 9,600
4 = On fallback to 12,000
5 = On fallback to 14,400
6 = On fallback to 16,800
NOTE: Rate Auto-Originate is valid only when V.32bis Autorate is
enabled (S76=0).