Model 3830 S-Registers
S57 Remote Access Password
Register allows entry of the second of digits of a remote access
password. Any value from 00 to 99 is valid. For example, if the remote
access password is 12345678, then S57=34.
S58 Remote Access Password
Register allows entry of the third of digits of a remote access password.
Any value from 00 to 99 is valid. For example, if the remote access
password is 12345678, then S58=56.
S59 Remote Access Password
Register allows entry of the fourth pair (rightmost) of digits of a remote
access password. Any value from 00 to 99 is valid. For example, if the
remote access password is 12345678, then S59=78.
S61 CT111 Rate Control
Determines if CT111 Rate is disabled, set for Fallback 1 or Fallback 2.
CT111 Rate allows the DTE to control modem rate via Pin 23 of the
EIA-232-D interface. This configuration option determines the effect of the
DTE Rate Control signal. It is only valid in Async Direct mode and
Synchronous mode. For proper operation, disable the V32bis Autorate
(S76) and V32bis Automode (S78) configuration options.
Register has the following values:
0 = Disable
1 = Fallback 1
2 = Fallback 2