Paradyne 3830 Network Card User Manual


 
4. AT Command Set and S-Registers
4-473830-A2-GB91-30 August 1998
Table 4-3
(18 of 20)
Model 3830 S-Registers
S84 AT Command Mode
Determines how the modem responds to valid and invalid AT commands.
The selections No ERROR and No Strap or ERROR permit installation
into applications that are customized for a different modem.
Register has the following values:
0 =Normal.
1 =No ERROR. The modem executes all valid commands, ignores invalid
commands, and never issues an ERROR message.
2 =No Strap or ERROR. The modem ignores all configuration
commands, but always issues an OK response message.
Factory setting is Normal.
S85 Fast Disconnect
Allows the modem to disconnect immediately after receiving a disconnect
command from a local DTE or its own diagnostic control panel.
Register has the following values:
0 = Disable
1 = Enable
Factory setting is Disable.
S88 Straps When Disconnected
Determines if configuration options in the Active (Saved) configuration
area are loaded to Active (Operating) when the modem disconnects.
Register has the following values:
0 or 231 = No Change
1 or 232 = Reload
Factory setting is No Change.