Paradyne 8779 Network Hardware User Manual


 
Configuration Options
A-18
8700-A2-GB20-00April 2000
Set Cross-Connect Mode
For Cross-Connect Mode configuration options, refer to Table A-9. To access the
Set Cross-Connect Mode screen, follow this menu selection sequence:
Main Menu Configuration Load Configuration
From Cross-Connect Set Cross-Connect Mode
main/config/xconnect_mode
Slot: 18 Model: 87xx
CROSS-CONNECT MODE
DSX-1 | G.703 Port MODE DSL Port
1 DS1 Bypass
1
2 DS1 Bypass
2
3 DS1 Bypass
3
4 DS1 Bypass
4
5 DS1 Bypass
5
6 DS1 Bypass
6
7 DS1 Bypass
7
8 DS1 Bypass
8
Assign_DS0s
––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––
Ctrl-a to access these functions, ESC for previous menu M
ainMenu Exit
S
ave Clear_All
If any port Mode is DS0 Cross-connect, selecting Assign_DS0s causes the
Assign Time Slots screen to be displayed.
The Clear_All command changes the Mode of all enabled ports to DS0
Cross-Connect. All DSL port numbers and time slot assignments are cleared.
For information about the cross-connection system, see Chapter 4,
Cross-Connecting Ports.