Paradyne 8779 Network Hardware User Manual


 
Configuration Options
A-12
8700-A2-GB20-00April 2000
Table A-7. System Options (2 of 2)
Telco Initiated Loopback
Possible Settings (Models 8747, 8777): Enable, Disable
Default Setting: Enable
Determines if the unit will respond to Telco loopback commands on the DSX-1 interface.
See Telco-Initiated Tests in Chapter 8, Testing.
Enable The unit will respond to Telco loopback commands.
Disable The unit will not respond to Telco loopback commands.
Remote Telco Line Loopback
Possible Settings (Models 8747, 8777): Enable, Disable
Default Setting: Disable
Determines if the unit will perform a Telco initiated loopback on just the local unit or if
the loopback will be performed on the remote DSL unit. See Telco-Initiated Tests in
Chapter 8, Testing.
Enable The loopback will be in the remote unit.
Disable The loopback will be local.
G.703 Line Termination
Possible Settings (Model 8779): 75 ohms, 120 ohms
Default Setting: 120 ohms
Specifies the impedance of the G.703 interface
75 ohms The G.703 interface impedance is 75 ohms unbalanced.
120 ohms The G.703 interface impedance is 120 ohms balanced.