Table A-4. DSX-1 Interface Options (2 of 2)
Line Framing
xx
Possible Settings: ESF, D4
Default Setting: ESF
Specifies the framing format to be used by the DSX-1 interface.
H Line Framing is only available when the unit is configured as an LTU. The NTU is
automatically configured to match the framing format used by the LTU.
ESF ESF framing formatting is used for transmitted and received data over the
DSX-1 Interface.
D4 D4 framing format is used for transmitted and received data over the DSX-1
Interface.
Line Equalization
Possible Settings: 0-133, 133-266, 266-399, 399-533, 533-655
Default Setting: 0-133
Compensates for signal distortion for a DSX-1 signal over a given distance.
0133 feet Provides equalization for a cable length up to 133 feet.
133266 feet Provides equalization for a cable length up to 266 feet.
266399 feet Provides equalization for a cable length up to 399 feet.
399533 feet Provides equalization for a cable length up to 533 feet.
533655 feet Provides equalization for a cable length up to 655 feet.
Excessive Error Rate Threshold
Possible Settings: 1E4, 1E5, 1E6, 1E7, 1E8, 1E9
Default Setting: 1E4
Determines the error rate at which an excessive error rate (EER) condition is
recognized. The rate is the ratio of the number of CRC errors to the number of bits
received in a certain period.
1E4 1E-9 The rate at which EER is recognized.
Primary Clock Source
Possible Settings: Internal, DSX-1
Default Setting: DSX-1
Specifies where the unit will derive its timing from.
H Primary Clock Source is available only when the unit is configured as an LTU and
the port is not cross-connected. If DSL Line Rate is set lower than 1552 kbps,
Primary Clock Source is forced to DSX-1 and cannot be changed.
Internal Timing is derived from the internal oscillator.