Paradyne 8779 Network Hardware User Manual


 
Standards Compliance for SNMP Traps
B-2
8700-A2-GB20-00April 2000
For a unit defined as an NTU running IP Conservative software, all traps have at
a minimum a variable binding of the Super Overloaded ifIndex (SOI). The formula
for the SOI is:
((LTU Slot Number) * 1,000,000)
+ ((LTU DSL Port Number) * 1,000)
+ the NTUs ifIndex.
warmStart
SNMP Trap Description Possible Cause
warmStart The unit has reinitialized
itself.
The trap is sent after the unit
resets and stabilizes.
No variable bindings.
H Reset command.
H Power disruption.
authenticationFailure
SNMP Trap Description Possible Cause
authenticationFailure Failed attempts to access
the unit.
Variable bindings:
H devAuthentication
FailureIPAddress
(Health & Status MIB)
Returns zero if the IP
address is unknown or the
failure came from the
terminal port.
Three unsuccessful attempts
were made to enter a correct
login/password combination.