Operation and Maintenance
5-13
9664-A2-GB20-00
March 2000
Health and Status Messages
The following table provides Health and Status messages that apply to the
FrameSaver unit.
Table 5-7. Health and Status Messages (1 of 2)
Message
What It Indicates
Auto-Configuration Active Auto-Configuration feature is active, which allows
automatic configuration and cross-connection of
DLCIs as they are reported by the network LMI.
Back-to-Back Mode Active The operating mode has been configured for
back-to-back operation (
Main Menu
→
Control
→
Change Operating Mode)
.
The FrameSaver unit can be connected to another
FrameSaver unit without a frame relay switch
between them.
This feature is useful for product demonstrations
or for a point-to-point configuration using a leased
line.
CTS down to Port-1 Device The user data port CTS control lead on the
FrameSaver unit is off.
DLCI
nnnn
Down,
frame relay link
1,2
The DLCI for the specified frame relay link is down.
DTR Down from Port-1 Device The DTR control lead from the device connected to
the user data port is deasserted.
Link
Down Administratively,
frame relay link
2
The specified frame relay link has been disabled
by the unit due to LMI Behavior conditions or LMI
Protocol on another link is in a failed state.
1
nnnn
indicates a DLCI number of 16 through 1007.
2
frame relay link
is one of the following:
– Net1-FR1. The frame relay link specified for the network interface, Network 1.
– Port-1. The frame relay link associated with the user data port.