Operation and Maintenance
5-3
9664-A2-GB20-00
March 2000
Viewing LEDs and Control Leads
The FrameSaver unit’s faceplate includes LEDs (light-emitting diodes)
that provide status on the FrameSaver unit, its network interface, and its user
data port.
00-16654
OK
ALM
TST
OK
OK
9664
NETWORK PORT
FrameSaver
TM
SLV
FrameSaver
®
SLV
The Display LEDs and Control Leads screen allows you to monitor a remote unit
and is useful when troubleshooting control lead problems. The appropriate
interfaces are shown on this screen, with the appropriate status highlighted.
Main Menu
→
Status
→
Display LEDs and Control Leads
Display LEDs & Control Leads Screen
main/status/leds 9664
Device Name: Node A 5/26/1999 23:32
DISPLAY LEDS & CONTROL LEADS
SLOT: 1 - LL S/T FR NAM
GENERAL
NETWORK1 Port-1
OK OK OK
Alarm TXD
Test RXD
DTR
RTS(Control)
––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––
ESC for previous menu M
ainMenu Exit
R
efresh
Refresh the screen to view control lead transitions. LED and control lead
descriptions are in the sections that follow.