Table 6-9. Device Messages (3 of 5)
Message What To DoWhat It Indicates
Limit of PVC
Connections reached
New was selected from the
PVC Connection Table and
the maximum number of
PVCs has already been
created.
H Do not create the PVC
connection.
H Delete another PVC
connection, and try again.
Link Inactive You attempted to start a
PVC test on an inactive
link.
Activate the link or test a different
link.
Name Must be Unique Name entered for a
management PVC has
been used previously.
Enter another 4-character name
for the logical/management link.
No circuits available
for Mgmt PVC
New was selected from the
Management PVCs option
screen, but all configured
DLCIs have been
connected.
Configure more network and/or
Port-1 DLCIs and try again.
No DLCIs available for
connection
New was selected from the
PVC Connection Table, but
all configured DLCIs have
been connected.
H No action needed.
H Configure more DLCIs and try
again.
New was selected from the
Management PVCs option
screen, but all Link/DLCI
pairs have been connected.
Configure more network and/or
Port-1 Links/DLCIs pairs and try
again.
No DLCIs Defined DLCI Records was selected
from an interface’s
Configuration Edit/Display
menu, and no DLCI
Records have been created
for this interface.
Select New and create a DLCI
record.
No more DLCIs
allowed
New or CopyFrom was
selected from an interface’s
DLCI Records configuration
screen, and the maximum
number of DLCI Records
had already been reached.
Delete a DLCI, then create the
new DLCI record.
No more PVCs
allowed
CreatePVC was selected
on the DLCI Records
configuration screen, and
the maximum numbers of
PVCs for the device has
already been created.
Delete a PVC, then create the
new PVC.
No Security Records
to Delete
Delete was selected from
the Administer Login
screen, and no security
records had been defined.
H No action needed.
H Enter a security record.