Paradyne 9820 Computer Monitor User Manual


 
SNMP MIBs and Traps, and RMON Alarm Defaults
B-19
9820-A2-GB20-20
June 2000
DLCI Alarm Defaults – Paradyne Area
These alarms apply to all DLCIs on the network interface and can be created
during RMON initialization or when a DLCI is created. They are put into the
Paradyne alarm area.
Table B-12. DLCI Alarm Defaults – Paradyne Area (1 of 2)
Item
Sample
Type
1
MIB/Tag/OID
2
Interval
Event
Type
Rising
Threshold
Default
Falling
Threshold
Default
DLCI Inactive
Seconds
D
MIB:
pdn_FrExt.mib (E)
Tag:
devFrExtDlciStsInactive-
Secs
OID:
.1.3.6.1.4.1.1795.2.24.2.
6.9.4.2.1.2.I.D
900 secs
(15 mins)
Rising 1 1
Missing Latency
Responses
D
MIB:
pdn_FrExt.mib (E)
Tag:
devFrExtDlciMissedSLVs
OID:
.1.3.6.1.4.1.1795.2.24.2.
6.9.4.1.1.23.I.D
900 secs
(15 mins)
Rising 5 5
Rx FECNs D
MIB:
FR DTE MIB
(RFC 2115)
Tag:
frCircuitReceivedFECNs
OID:
.1.3.6.1.2.1.10.32.2.1.
4.I.D
60 secs
(1 min)
Rising 1 1
Rx BECNs D
MIB:
FR DTE MIB
(RFC 2115)
Tag:
frCircuitReceivedBECNs
OID:
.1.3.6.1.2.1.10.32.2.1.
5.I.D
60 secs
(1 min)
Rising 1 1
Congested Seconds D
MIB:
pdn_FrExt.mib (E)
Tag:
devFrExtDlciSts-
CongestedSecs
OID:
.1.3.6.1.4.1.1795.2.24.2.
6.9.4.2.1.6.I.D
60 secs
(1 min)
Rising 5 5
Frames Dropped by
Network
D
MIB:
pdn_FrExt.mib (E)
Tag:
devFrExtDlciNetDropFr
OID:
.1.3.6.1.4.1.1795.2.24.2.
6.9.4.1.1.20.I.D
60 secs
(1 min)
Rising 1 1