Paradyne 9820 Computer Monitor User Manual


 
Monitoring
6-19
9820-A2-GB20-20
June 2000
Table 6-11. Health and Status Messages (2 of 2)
Message What It Indicates
Ethernet Link Down (Model 9820-45M) The Ethernet port is
administratively enabled, but communication is not
possible.
Fan Failure (Model 9820-45M) At least one fan has failed.
Link
Down Administratively,
frame relay link
2
The specified frame relay link has been disabled
by the unit due to LMI Behavior conditions or LMI
Protocol on another link is in a failed state.
This is not an alarm condition so System
Operational appears, as well.
LMI Discovery in Progress,
frame relay link
2
Local Management Interface protocol discovery is
in progress to determine which protocol will be
used on the specified frame relay link.
LMI Down,
frame relay link
2
The Local Management Interface(s) has been
declared down for the specified frame relay link.
LOS at Network
1 A Loss of Signal (LOS) condition is detected on the
network data port. Either the control leads on the
network data port are deasserted, the TM lead is
asserted, or no clock is detected from the NTU.
Network Com Link Down The communication link for the COM (Terminal)
port is down, and the port is configured for Net
Link.
Power Supply Failure (Model 9820-45M) Power supply voltage has
dropped below an acceptable level.
SLV Timeout, DLCI
nnnn
,
frame relay link
1,
2,
3
An excessive number of SLV communication
responses from the remote FrameSaver SLV unit
have been missed on the specified multiplexed
DLCI; the DLCI is not suitable for user data.
;
When a hardware bypass capable device has
been detected at the other end of the PVC and this
condition occurs, only user data for EDLCI 0 will be
transmitted while this condition exists.
Two Level-1 Users Accessing
Device
Two Level 1 users are already using the menu-
driven user interface; only two sessions can be
active at one time.
1
nnnn
indicates a DLCI number of 16 through 1007.
2
frame relay link
is one of the following:
– Net1-FR1. The frame relay link specified for the network interface, Network 1.
– Port-1. The frame relay link associated with the user data port.
3
Does not apply to a TS Management Link DLCI.