Patton electronic 1088/D Modem User Manual


 
21
lish a connection after the framer begins seeing unframed pack-
ets. The Test Model Timing Chart below shows the amount of
time the framer must see consecutive unframed packets before
the unit will restart and try to establish a new line connection.
The reason that there are different Restart Times will become
apparent after reading the rest of the document. The 511/511E
Time Out shown refers to the amount of time the 511/511E pat-
tern will be valid. At the end of this time the pattern will automat-
ically turn itself off and the normal data path will be re-
established. The ER led will flash indicating to the user that the
test has timed out. The ER led will stop flashing once the 511/
511E switch is placed into the normal position.
Symbol Indicators
Test Mode Timing
Item Elapsed Time (seconds)
Start Up 50
Data Mode 4
511/511E Generator Enabled 60 (The generator will stop after 45 seconds.)
Remote End of an RDL 60
511/511E Time Out 45 (The pattern generator will automatically turn
off after 45 seconds. The ER LED will flash until
the user turns off the 511/511E switch.)
This symbol designates the origination or the
termination of a data path. The direction of the
arrow connected distinguish the two data paths.
This symbol designates an invalid data path. If
there is data present it should be ignored.