Paxar 2 Printer User Manual


 
Option 50 (Bar Code Density)
You can apply this option to bar code fields when you want to
create custom densities. When you apply this option, it overrides
the density value in the bar code field.
When using this option, set the density parameter in your bar code
field to the default value. You can only use this option once for
each bar code field. This option overrides the density selected in
the bar code field.
Bar codes produced using Option 50 may not be scannable. The
additional character gap, narrow space, and wide space
parameters are valid
only
with Code 39 and Codabar. If these
parameters are specified for any other bar codes, they will be
ignored by the printer.
Do not use Option 50 with UPC or EAN bar
codes.
Syntax
R,50,narrow,wide,gap,nar_space,
wide_space
p
R1. R Field Option Header.
R2. 50 Option
50
.
R3. narrow Dot width of the narrow element. Range:
1
-
99
.
R4. wide Dot width of the wide element. Range:
1
-
99
.
R5. gap Additional dot space between characters. Enter a value of
1
-
99
. (Code 39 and Codabar only.)
R6. nar_space Additional dot width of the narrow bar code space. (Code 39
and Codabar only). Range:
1
-
99
.
R7. wide_space Additional dot width of the wide bar code space. (Code 39
and Codabar only). Range:
1
-
99
.
Example
R,50,4,8,4,4,8
p
Creates a custom bar code density with a narrow element of 4
dots, a wide element of 8 dots, a gap of 4 dots, 4 additional dot
widths for the narrow bar code space, and 8 additonal dot widths
for the wide bar code space (if this is a Code 39 or Codabar bar
code).