Adjusting the Supply Sensor
The supply sensor controls how much supply feeds between
tags or labels. The sensor reads black marks or feed apertures.
To read black marks or apertures, the sensor must be aligned
with the black mark or aperture on the tag. Otherwise, you’ll
see an error message when you try to print a batch.
When moving the sensor, turn the sensor adjustment knob:
•
CLOCKWISE
to move the sensor away from the inside
edge of the supply.
•
COUNTERCLOCKWISE
to move the sensor toward
the inside edge of the supply.
Sensor
Adjustment
Knob
9445 Equipment Manual