34 Pelco Manual C1921M-G (1/04)
1. Press the SPOT MONITOR key. The green LED over the
SPOT key lights.
2. Select a camera on the multiplexer you want to sequence.
Addressing by Multiplexer (Switch 7 OFF)
a. On the number pad, press the multiplexer’s address
number (1-16 if the keyboard is connected to the
multiplexer; 1-8 if connected to a server), and then
press the UNIT key. The LED displays the address.
b. On the number pad, press the camera number (1-16),
and then press the CAM key.
Addressing Consecutively (Switch 7 ON)
On the number pad, press the camera number, and then
press the CAM key. Refer to Table A for camera numbers.
3. Press the SEQ key.
1. Press the MAIN or SPOT MONITOR key.
2. On the number pad, press the multiplexer’s address number
(1-16 if the keyboard is connected to the multiplexer; 1-8 if
connected to a server), and then press the UNIT key. The
LED displays the address.
3. Press the SEQ key.
1. Select the desired multi-camera display.
2. Press and hold the multi-camera display key to enter multi-
screen programming mode. A bar appears in the first camera
location.
3. Use the joystick to move the on-screen bar to the desired
camera location for sequencing, and press the SEQ key to
initiate the sequencing of all active cameras.
Hold down the SEQ key for about three seconds.
Table E. Operation Guide (Continued)
OPERATION KEYBOARD COMMAND RESULT
(Continued on next page)
Sequence multiplex-
ers connected to a
server.
Sequence
multiplexers
connected to a
server and
sequence cameras
on a multiplexer(s).
Starts sequencing the
multiplexers in numerical
order, displaying the main
monitor first, and then the spot
monitor. Monitors to be
displayed are selected in the
Set Sequence submenu of the
server’s Monitor menu.
Sequencing appears on the
monitor affiliated with the
keyboard; for example, if the
keyboard is set for address 1,
the sequence appears on
monitor 1.
Starts the sequence of
individual cameras on the
spot monitor.
Run a sequence of
cameras from one
multiplexer on the
spot monitor.
(SPOT MONITOR
DISPLAY in the
Advanced System
Setup menu must
be in SEQUENCE.)
Stop a sequence of
cameras on a
multiplexer.
Stops the sequence. The
monitor displays video from
the camera on which
sequence stops.
The sequence will run until
the SEQ key is pressed or
until another camera or multi-
screen display is selected.