To test optical transceivers ensure a fiber link is present.
Examples
The following example displays the optical transceiver diagnostics.
console# show fiber-ports optical-transceiver
Port Temp Voltage Current Output Input LOS
Power Power Power
------ -------- ------------ ------------ ----------- ---------- ---------
g1 W OK E OK OK OK
g2 OK OK OK OK OK OK
e3 Copper
Temp – Internally measured transceiver temperature.
Voltage - Internally measured supply voltage.
Current – Measured TX bias current.
Output Power – Measured TX output power.
Input Power – Measured RX received power.
Tx Fault – Transmitter fault
LOS – Loss of signal
Data ready – Indicates transceiver has achieved power up and data is ready.
N/A - Not Available, N/S - Not Supported, W - Warning, E - Error
The following example displays detailed optical transceiver diagnostics
console# show fiber-ports transceiver detailed
Port Temp Voltage Current Output Input LOS
[C] [Volt] [mA] Power Power
[mWatt] [mWatt]