Polycom KWS300 Server User Manual


 
Introduction to KIRK Wireless Server 300
2–4
Administrative Computer
An administrative computer is required for configuration and maintenance of
the KWS300. This computer may be temporarily connected to the network. A
dedicated computer is not required.
Requirements for the KIRK Wireless Server 300 Solution
This section provides information about the environmental and electrical
requirements and software requirements for the KWS300 solution.
KIRK Wireless Server 300
Environmental Requirements
The installation area must be:
clean, free of traffic and excess dust, dry, and well ventilated
within the temperature ranges of 10°C and 40°C/50°F and 104°F
between 20% and 80% non-condensing relative humidity
Electrical Requirements
The following electrical requirements must be met:
Power over Ethernet (PoE 802.3af)
Maximum power supply consumption is 3.0W (IEEE 802.3af class 1
device).
Use a standard PoE adapter or a PoE-enabled port on a switch adhering to PoE
802.3af when connecting the server to a PoE power source.
Installation Prerequisites
Before you start the installation you need to find the following information:
ARI code (serial number) for the KWS300 (see label on the rear of the KWS
unit)
Note
The installation area must be of sufficient height from the floor to prevent
water damage.