Q-Logic 59047-09 C Switch User Manual


 
5 – Fibre Alliance MIB Objects
Connectivity Table
5-8 59047-09 C
S
Syntax
INTEGER
Access
read-only
Status
mandatory
Return Value
Refer to Tabl e 5-3 for connectivity unit return values. Return value will be OK
(3), unless one or more of the following occurs.
Refer to Tabl e 5-4 for connectivity unit return values. Return value will be OK
(3), uninstalled IO or CPU boards are ignored
Table 5-3. SANbox 5000 Series Connectivity Unit Return Values
Status Return Value
If one power supply is reporting Bad
and/or not installed
warning (4)
If both power supplies are reporting Bad
and/or not installed
failed (5)
If one or more cooling fan failed warning (4)
If all cooling fans failed failed (5)
If temperature status = "Warm" warning (4)
If temperature status = "Overheating" failed (5)
If any port down warning (4)
If POST failed failed (5)
If switch Offline or in Diagnostics mode warning (4)
Table 5-4. SANbox 9000 Series Connectivity Unit Return Values
Status Return Value
If either FAN or PS boards are not installed warning (4)
If all FANs or all PS boards are not
installed
failed (5)