Q-Logic 59047-09 C Switch User Manual


 
6 – Fabric Element MIB Objects
The Status Group
6-12 59047-09 C
S
fcFxPortHoldTime (1.3.6.1.2.1.75.1.1.5.1.14)
The maximum time, in microseconds, that the FxPort shall hold a frame before
discarding the frame if it is unable to deliver the frame. The value 0 means that the
FxPort does not support this parameter.
Syntax
MicroSeconds
Access
read-only
Status
current
Return Value
The default ED_TOV parameter is: 2000 (0x7D0).
The Status Group
The objects described in this section are in table format indexed by switch index
and port index. An example of how to access one of these objects is: "snmpget
localhost public fcFxPortId.1.1". This group consists of tables that contain
operational status and established service parameters for the Fabric Element and
the attached NxPorts.
This group consists of tables that contains operational status and established
service parameters for the Fabric Element and the attached NxPorts. This table
contains one entry for each FxPort, and the operational status and parameters of
the FxPorts.
fcFxPortID (1.3.6.1.2.1.75.1.2.1.1.1)
The address identifier by which this FxPort is identified within the fabric. The
FxPort may assign its address identifier to its attached NxPort(s) during Fabric
Login.
Syntax
FcAddressId
Access
read-only
Status
current