Q-Logic 59047-09 C Switch User Manual


 
5 – Fibre Alliance MIB Objects
Link Table
59047-09 C 5-51
A
connUnitLinkIndex (1.3.6.1.3.94.1.12.1.2)
This index is used to create a unique value for each entry in the link table with the
same connUnitLinkUnitId. The value can only be reused if it is not currently in use
and the value is the next candidate to be used. This value wraps at the highest
value represented by the size of INTEGER. This value is reset to zero when the
system is reset, and the first value to be used is one.
Syntax
INTEGER (1..2147483647)
Access
read-only
Status
mandatory
Return Value
The table index.
connUnitLinkNodeIdX (1.3.6.1.3.94.1.12.1.3)
The Node WWN of the unit at one end of the link. If the Node WWN is unknown
and the Node is a connUnit in the responding agent, then the value of this object
must be equal to its connUnitID.
Syntax
OCTET STRING (SIZE(16))
Access
read-only
Status
mandatory
Return Value
The World Wide Name of the local switch for each entry in the link table. For
example, 10 00 00 C0 DD 00 71 C9 00 00 00 00 00 00 00 00.
connUnitLinkPortNumberX (1.3.6.1.3.94.1.12.1.4)
The port number on the unit specified by connUnitLinkNodeIdX if known,
otherwise -1. If the value is non-negative, then it will be equal to
connUnitPortPhysicalNumber.