Removal/Replacement
This section describes the removal and replacement procedures for the following
field replaceable units (FRU):
SFP transceivers
Power supplies for model 5202/5602 switches
The switch is equipped with a battery that powers the non-volatile memory. This
memory stores the switch configuration. The battery is not a field replaceable unit.
6.1
SFP Transceiver Removal and Replacement
The SFP transceivers can be removed and replaced while the switch is operating
without damaging the switch or the transceiver. However, transmission on the
affected port will be interrupted until the transceiver installed.
To remove a transceiver, gently press the transceiver into the port to release the
tension, then pull on the release tab or lever and remove the transceiver. Different
transceiver manufacturers have different release mechanisms. Consult the
documentation for your transceiver. To install, insert the transceiver into the port
and gently press until it snaps in place.
WARNING!!
Danger of explosion if battery is incorrectly replaced. Replace only
with the same or equivalent type recommended by the
manufacturer. Dispose of the used battery according to the
manufacturer’s instructions.
WARNUNG!!
Bei unsachgemäß ausgetauschter Batterie besteht
Explosionsgefahr. Die Batterie nur mit der gleichen Batterie oder
mit einem äquivalenten, vom Hersteller empfohlenen Batterietyp
ersetzen. Die gebrauchte Batterie gemäß den
Herstelleranweisungen entsorgen.
AVERTISSEMENT!!
Danger d’explosion si le remplacement de la pile est incorrect. Ne
remplacer que par une pile de type identique ou équivalent
recommandé par le fabricant. Jeter la pile usagée en observant les
instructions du fabricant.
NOTE: The SFP transceiver will fit only one way. If the SFP does not install