Q-Logic 59096-04 Switch User Manual


 
4 – Installation
Installing a Switch
59096-04 A 4-11
A
4.2.5
Connect the Switch to AC Power
WARNING!! This product is supplied with a 3-wire power cable and plug for the
user’s safety. Use this power cable in conjunction with a properly
grounded outlet to avoid electrical shock. An electrical outlet that is
not correctly wired could place hazardous voltage on metal parts of
the switch chassis. It is the responsibility of the customer to ensure
that the outlet is correctly wired and grounded to prevent electrical
shock.
You may require a different power cable in some countries
because the plug on the cable supplied with the equipment will not
fit your electrical outlet. In this case, you must supply your own
power cable. The cable you use must meet the following
requirements:
For 125 Volt electrical service, the cable must be rated at 10
Amps and be approved by UL and CSA.
For 250 Volt electrical service: The cable must be rated at 10
Amps, meet the requirements of H05VV-F, and be approved by
VDE, SEMKO, and DEMKO.
AVERTISSEMENT!!
Pour la sécurité de l’utilisateur, l’appareil est livré avec un câble
d’alimentation trifilaire et une fiche. Pour éviter toute secousse
électrique, enficher ce câble à une prise correctement mise à la
terre.Une prise électrique dont les fils sont mal branchés peut créer
une tension dangereuse dans les pièces métalliques du châssis
switch. Pour éviter toute secousse électrique, s’assurer que les fils
sont correctement branchés et que la prise est bien mise à la terre.
Dans certains pays les prises électriques sont de modèle différent;
on ne peut y enficher le câble de l’appareil. On doit donc en utiliser
un autre ayant les caractéristiques suivantes:
Alimentation 125 V: Câble pour courant nominal de 10 A,
agréé LAC et CSA.
Alimentation 250 V: Câble pour courant nominal de 10 A,
conforme au H05VV-F, et agréé VDE, SEMKO et DEMKO.